Specifications
Single Gas detector
Replaceable modularized sensor
Wall-mounted //4~20mA SIGNAL
Online monitor
Stand alone gas detector
Product Overview:
TR series single channel wall-mounted gas detector can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas.
The gas detector detects gas concentration in natural diffusion way, and uses electric chemical sensor or catalytic combustion type sensor; big LCD displays the concentration of the leaked gas real time.
If the concentration exceeds the preset alarm level, detector will start the acoustic-optical alarm or exhaust system; international standard signal of 4-20mA can be directly connected into the factory DCS system, RS4845 digital signal is connected with factory’s principle computer; the device adopts embedded micro controlling technique.
Stand-alone gas detector: AC 220V
Main features:
1 Adopts advanced embedded micro controller(16 digit ultra-low power consumption )
2 128*64 dot matrix ultra-large LCD
3 User can set the alarm level
4 Displaying the time of fist alarm
5 Real-time clock
6 Replaceable modularized sensor
7 Automatic calibration function, reduce the measuring error.
8 Automatically save alarm data for 1000 articles
9 standby battery can work more than 100 hours in the condition that do not alarm (optional)
10 standard signal(4-20mA) can be directly connected to factory's DCS system (optional)
11 RS4845 digital signal is connected to factory’s principle computer (optional)
Technical parameters:
Detecting Gas |
oxygen O2 |
Measuring Range |
0-30%VOL |
Deviation |
≤± 3% F.S |
Respond Time |
T90 < 30 s |
Display Mode |
128*64 dot matrix ultra-large liquid-crystal display for data and system condition |
Alarm Level |
two levels' alarm. Users can set it. |
Alarm Output |
relay output, volume AC 220V/2A. |
Signal Output |
standard signal (4-20mA) can be directly connected to factory's DCS system (optional) RS4845 digital signal is connected with factory’s principle computer (optional) |
Working Temperature |
toxic gas: -20°C~ + 50 °C combustible gas: - 40 °C ~ + 70 °C |
Working Humidity |
< 90% R.H. no condensation |
Working Voltage |
AC220V / 50HZ |
Spare Battery (optional) |
continuously work more than 100 hours in the condition that do not alarm. can continuously work 8 hours for combustible gas detector |
Protection Class |
IP65 |
Weight |
about 1.2kg |