Specifications
fixed gas leakage monitor
fixed explosion-proof shell
high precision
easy installation and maintenance
5 year sensor life
Product Overview:
TR500-O2 fixed oxygen gas monitor (also called gas detector): with 6 years experience in designing and producing detector, we develop our new product with electrochemical sensor. It can be widely used in metallurgy, petrol, petrifaction, chemistry, light industry, coking, municipal administration, gas, pharmacy, sewage dealing and many other special industries and fields.
TR500-O2 fixed oxygen gas monitor can monitor the concentration of oxygen. The monitor adopts intrinsic safety type channel design, standard 4~20mA two wires signal output. It can transfer data in long distance, can get into the DSC system directly. it is among the first class in similar products in China.
Main features:
1 It can detect more kinds of gas. high precision
2 Fixed explosion-proof shell; it’s safe and reliable
3 Standard 4-20mA electric current output, compatible with existing alarm control unit or DSC (distributed control system).
4 best sensor, high sensitivity, rapid response, stable and reliable
5 operation is simple; easy installation and maintenance
Technical parameters:
Detecting Gas |
oxygen |
Working Temperature |
- 20 °C ~ + 50 °C |
Relative Humidity |
≤90%R.H. no condensation |
Technical Parameters |
Working voltage: 16~30VDC |
Working current: KQ500-EX is 120mA, others ≤50 mA |
|
Output signal: 4~20mA standard signal two wire type output (KQ500-EX three wire type) |
|
Sensor |
electrochemical sensor; catalytic combustion type sensor for KQ500-EX |
Respond Time |
T90<30s |
Weight |
≤900g |
Fixing Parameters |
Fixing type: wall-mounted type |
Transition cable: two core shield cable (KQ500-EX uses three core shield cable), section 2×1.5mm2, external diameter 10mm |
|
Transmission distance ≤1000m |
|
Explosion-proof Level |
Exd IICT6(used for explosion proofing detector);ExiaIICT4(used for intrinsic safety type detector) |
Protection Class |
IP66 |